VeraSol
Skip Page Header

Silver Gallery | ME-103-DC

Return to the Page Header

Snapshot Details

  • Product Type: Ceiling Fan
  • Model Number: ME-103-DC
  • Size [measured, diameter in mm]: 1190
  • Power Supply Type: DC
  • Nominal Conditions: Air Delivery [m3/min]: 147.3
  • Nominal Conditions: Power Input at Max Speed [W]: 24.2
  • Nominal Conditions: Energy Efficiency Value [m3/min/W]: 6.09
  • Retail Price [USD]: N/A
Product Information
  • Brand tooltip Product brand name as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet Silver Gallery
  • Product Type Ceiling Fan
  • Model Number tooltip Model number as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet ME-103-DC
  • Size [measured, diameter in mm] 1190
  • Power Supply Type DC
  • Manufacturer tooltip Name of the manufacturer Metropolitan Electrical Appliance Mfg. Co.Ltd
  • Country of Manufacture tooltip Country where the product is manufactured China
  • Warranty [months] tooltip Duration of the consumer-facing product warranty that covers manufacturing defects under normal use Not stated
  • Rated Input Power [W] tooltip Required power input as specified by manufacturer 35
  • Rated Input Voltage [V] tooltip Required voltage input as specified by manufacturer 12
  • Type of Plug or Connector Included with Product to Connect to Energy Supply
Fan Features
  • Number of Regulated Speeds 5
  • Timer No
  • Light No
  • Oscillation Not tested
  • Oscillation Movement [degrees] Not tested
  • Vertical Angular Movement Not tested
  • Vertical Angular Movement [degrees] Not tested
  • Height [cm] Not tested
  • Maximum Adjusted Height [cm] Not tested
Test Setup
  • Test Voltage [V]
  • Test Current [A]
  • Test Setup Notes
Nominal Conditions: Performance
  • Nominal Conditions: Air Delivery [m3/min] tooltip Amount of airflow delivered by the fan when set at maximum speed 147.3
  • Nominal Conditions: Power Input at Max Speed [W] tooltip Amount of power required to operate the product when the fan setting is at the highest speed 24.2
  • Nominal Conditions: Energy Efficiency Value [m3/min/W] tooltip Volume of airflow delivered by the product per Watt of input power Higher value means higher efficiency 6.09
  • Nominal Conditions: Highest Regulated Speed [RPM] 307
Over-Voltage Conditions: Performance
  • Over-Voltage Conditions: Air Delivery [m3/min] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 168.39
  • Over-Voltage Conditions: Power Input at Max Speed [W] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 32.9
  • Over-Voltage Conditions: Energy Efficiency Value [m3/min/W] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 5.12
  • Over-Voltage Conditions: Highest Regulated Speed [RPM] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 344
Under-Voltage Conditions: Performance
  • Under-Voltage Conditions: Air Delivery [m3/min] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 124.82
  • Under-Voltage Conditions: Power Input at Max Speed [W] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 15.3
  • Under-Voltage Conditions: Energy Efficiency Value [m3/min/W] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 8.14
  • Under-Voltage Conditions: Highest Regulated Speed [RPM] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 264
Post Environment Conditions: Performance
  • Post Environment Conditions: Air Delivery [m3/min] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 148.9
  • Post Environment Conditions: Power Input at Max Speed [W] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 24.6
  • Post Environment Conditions: Highest Regulated Speed [RPM] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 310
Ingress Protection
  • Ingress Protection Rating [IP number] tooltip Rates the effectiveness of the sealing of electrical enclosures against intrusion from foreign bodies (eg fingers, tools, dirt, etc) IP30
  • IP Test Results [Pass/Fail] Pass
  • Notes About Ingress Protection Product passed IP30 but failed IP40
Drop Test
  • Is there any damage to the motor after the drop test? Not tested
  • Is there any damage to the fan blade after the drop test? Not tested
  • Is there any damage to the fan guard after the drop test? Not tested
  • Is there any damage to the on/off switch after the drop test? Not tested
Overall Product Quality Inspection
  • Is the fan fitted with two or more well-balanced blades made from metal or other suitable material so as to be reasonably free from vibration? Yes
  • Are the bearings of good quality and lubricated appropriately for use? Yes
  • Is there an automatic shutdown mechanism when fan blades are impeded? No
  • Is the fan clearly marked with a standard nameplate? Prototype nameplate containing information on manufacturer name, model number, input voltage, frequency and power consumption
  • Notes About Nameplate No
  • Does the fan's packaging include appropriate information? Manufacturer name, model number, trade mark, gross weight, date of manufacture, and country of manufacture not provided. Rated power is inconsistent with that on rating label
  • Notes About Packaging No
  • Does the fan come with appropriate documentation? User manual and warranty information not provided
  • Notes About Documentation N/A
  • Are the fan blades appropriately guarded in accordance with Clause 20.101 of "IEC 60335-2-80: Household and similar electrical appliances. Safety. Particular requirements for fans."? No
Off-Grid Compatibility
  • Does the fan have its own low voltage disconnect (LVD) & reconnect (LVR) circuit or similar automatic shutdown mechanism to protect batteries from unintended drainage? No
  • Notes About LVD and LVR N/A
  • Is the LVD/LVR/timer function adequately described in the user manual or product packaging? No
Sampling And Testing Information
  • Sample Location Manufacturer Warehouse
  • Retail Price [USD] N/A
  • Test Completion Date [MM/DD/YYYY] 5/4/2016
  • Test Laboratory Name TUV SUD Hong Kong
Awards
  • Global LEAP Awards Winner (2015-2016)