VeraSol
Skip Page Header

Superfan | Super X1

Return to the Page Header

Snapshot Details

  • Product Type: Ceiling Fan
  • Model Number: Super X1
  • Size [measured, diameter in mm]: 1200
  • Power Supply Type: AC
  • Nominal Conditions: Air Delivery [m3/min]: 180.52
  • Nominal Conditions: Power Input at Max Speed [W]: 34.5
  • Nominal Conditions: Energy Efficiency Value [m3/min/W]: 5.23
  • Retail Price [USD]: N/A
Product Information
  • Brand tooltip Product brand name as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet Superfan
  • Product Type Ceiling Fan
  • Model Number tooltip Model number as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet Super X1
  • Size [measured, diameter in mm] 1200
  • Power Supply Type AC
  • Manufacturer tooltip Name of the manufacturer VERSA
  • Country of Manufacture tooltip Country where the product is manufactured India
  • Warranty [months] tooltip Duration of the consumer-facing product warranty that covers manufacturing defects under normal use 36
  • Rated Input Power [W] tooltip Required power input as specified by manufacturer 35
  • Rated Input Voltage [V] tooltip Required voltage input as specified by manufacturer 230
  • Type of Plug or Connector Included with Product to Connect to Energy Supply
Fan Features
  • Number of Regulated Speeds 5
  • Timer No
  • Light Yes
  • Oscillation Not tested
  • Oscillation Movement [degrees] Not tested
  • Vertical Angular Movement Not tested
  • Vertical Angular Movement [degrees] Not tested
  • Height [cm] Not tested
  • Maximum Adjusted Height [cm] Not tested
Test Setup
  • Test Voltage [V]
  • Test Current [A]
  • Test Setup Notes
Nominal Conditions: Performance
  • Nominal Conditions: Air Delivery [m3/min] tooltip Amount of airflow delivered by the fan when set at maximum speed 180.52
  • Nominal Conditions: Power Input at Max Speed [W] tooltip Amount of power required to operate the product when the fan setting is at the highest speed 34.5
  • Nominal Conditions: Energy Efficiency Value [m3/min/W] tooltip Volume of airflow delivered by the product per Watt of input power Higher value means higher efficiency 5.23
  • Nominal Conditions: Highest Regulated Speed [RPM] 393
Over-Voltage Conditions: Performance
  • Over-Voltage Conditions: Air Delivery [m3/min] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 180.69
  • Over-Voltage Conditions: Power Input at Max Speed [W] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 34.7
  • Over-Voltage Conditions: Energy Efficiency Value [m3/min/W] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 5.21
  • Over-Voltage Conditions: Highest Regulated Speed [RPM] tooltip Product is tested with an increased voltage (15% increase from the manufacturer’s rated input voltage) 396
Under-Voltage Conditions: Performance
  • Under-Voltage Conditions: Air Delivery [m3/min] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 180.61
  • Under-Voltage Conditions: Power Input at Max Speed [W] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 34.4
  • Under-Voltage Conditions: Energy Efficiency Value [m3/min/W] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 5.25
  • Under-Voltage Conditions: Highest Regulated Speed [RPM] tooltip Product is tested with a decreased voltage (15% decrease from the manufacturer’s rated input voltage) 393
Post Environment Conditions: Performance
  • Post Environment Conditions: Air Delivery [m3/min] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 185.53
  • Post Environment Conditions: Power Input at Max Speed [W] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 35
  • Post Environment Conditions: Highest Regulated Speed [RPM] tooltip Measured after the product is exposed to 40°C ± 2°C temperature and 93% ± 3% relative humidity for a minimum of 24 hours prior to testing 399
Ingress Protection
  • Ingress Protection Rating [IP number] tooltip Rates the effectiveness of the sealing of electrical enclosures against intrusion from foreign bodies (eg fingers, tools, dirt, etc) IP40
  • IP Test Results [Pass/Fail] Pass
  • Notes About Ingress Protection Product passed IP40
Drop Test
  • Is there any damage to the motor after the drop test? Not tested
  • Is there any damage to the fan blade after the drop test? Not tested
  • Is there any damage to the fan guard after the drop test? Not tested
  • Is there any damage to the on/off switch after the drop test? Not tested
Overall Product Quality Inspection
  • Is the fan fitted with two or more well-balanced blades made from metal or other suitable material so as to be reasonably free from vibration? Yes
  • Are the bearings of good quality and lubricated appropriately for use? Yes
  • Is there an automatic shutdown mechanism when fan blades are impeded? Yes
  • Is the fan clearly marked with a standard nameplate? N/A
  • Notes About Nameplate No
  • Does the fan's packaging include appropriate information? Gross weight or package dimension not provided
  • Notes About Packaging Yes
  • Does the fan come with appropriate documentation? N/A
  • Notes About Documentation N/A
  • Are the fan blades appropriately guarded in accordance with Clause 20.101 of "IEC 60335-2-80: Household and similar electrical appliances. Safety. Particular requirements for fans."? No
Off-Grid Compatibility
  • Does the fan have its own low voltage disconnect (LVD) & reconnect (LVR) circuit or similar automatic shutdown mechanism to protect batteries from unintended drainage? No
  • Notes About LVD and LVR N/A
  • Is the LVD/LVR/timer function adequately described in the user manual or product packaging? No
Sampling And Testing Information
  • Sample Location Manufacturer Warehouse
  • Retail Price [USD] N/A
  • Test Completion Date [MM/DD/YYYY] 5/4/2016
  • Test Laboratory Name TUV SUD Hong Kong
Awards
  • Global LEAP Awards Finalist (2015-2016)