Snapshot Details
- Product Type: Submersible Pump
- Model Number: Solar Submersible Pump 1 HP- 50 m
- Power Supply Type: DC
- Simulated PV Array Size [W]: 1200
- Simulated Head Value [m]: 50
- High Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day]: 14.6
Product Information
- Brand Product brand name as listed on consumer-facing materials, such as product package, nameplate, or product specification sheet Ecozen Solutions
- Product Type Submersible Pump
- Model Number Solar Submersible Pump 1 HP- 50 m
- Power Supply Type DC
- Manufacturer EcoZen Solutions
- Warranty [months] 60
- Rated Controller Input Power [W] Not rated
- Rated Controller Input Voltage [V] 400
- Battery Integrated [yes/no] No
Pump Information
- Pump Type Centrifugal
- Motor Type Permanent Magnet Sychronous Motor
- Pump Dimensions [L*W*H in cm] Not rated
- Rated Head Range [m] 0-50
- Rated Maximum Flow Rate [m3/h] Not rated
- Rated Pump Ingress Protection (IP) Rating Not rated
Test Setup
- Simulated PV Array Size [W] 1200
- Simulated Head Value [m] 50
Operating Range
- Minimum Irradiance Required to Start Pump [per 50W/m2] See test setup for simulated PV array size and head value used during testing 50
- Maximum Head [m] See test setup for simulated PV array size and head value used during testing 60.0
Maximum Efficiency at 700W/m2
- Maximum Wire-to-Water Efficiency [%] Simulated at 700W/m2 Simulating pump performance on a partly cloudy day (700W/m2 peak) 38%
- Head Value at Maximum Efficiency [m] Simulated at 700W/m2 Simulating pump performance on a partly cloudy day (700W/m2 peak) 31.0
- Flow Rate at Maximum Efficiency [L/min] Simulated at 700W/m2 Simulating pump performance on a partly cloudy day (700W/m2 peak) 56.3
Low Irradiance Day - Fully Cloudy (450W/m2 peak)
- Low Irradiance Day: Hydraulic Energy per Day [Wh/day] Simulating pump performance on a fully cloudy day (450W/m2 peak) Not achieved
- Low Irradiance Day: Average Wire-to-Water Efficiency [%] Simulating pump performance on a fully cloudy day (450W/m2 peak) Not achieved
- Low Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] Simulating pump performance on a fully cloudy day (450W/m2 peak) Not achieved
- Low Irradiance Day: Hours of Operation [h] Simulating pump performance on a fully cloudy day (450W/m2 peak) Not achieved
Average Irradiance Day - Partly Cloudy (700W/m2 peak)
- Average Irradiance Day: Hydraulic Energy per Day [Wh/day] Simulating pump performance on a partly cloudy day (700W/m2 peak) 487.4
- Average Irradiance Day: Average Wire-to-Water Efficiency [%] Simulating pump performance on a partly cloudy day (700W/m2 peak) 18%
- Average Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] Simulating pump performance on a partly cloudy day (700W/m2 peak) 3.6
- Average Irradiance Day: Hours of Operation [h] Simulating pump performance on a partly cloudy day (700W/m2 peak) 3.7
High Irradiance Day - Full Sun (1000W/m2 peak)
- High Irradiance Day: Hydraulic Energy per Day [Wh/day] Simulating pump performance on a fully sunny day (1000W/m2 peak) 1987.3
- High Irradiance Day: Average Wire-to-Water Efficiency [%] Simulating pump performance on a fully sunny day (1000W/m2 peak) 34%
- High Irradiance Day: Total Volume of Water Moved per Solar Day [m3/day] Simulating pump performance on a fully sunny day (1000W/m2 peak) 14.6
- High Irradiance Day: Hours of Operation [h] Simulating pump performance on a fully sunny day (1000W/m2 peak) 6.1
Product Quality Inspection
- Pump External Workmanship and Quality Evaluation [poor/satisfactory/good] Good
- Pump Internal Workmanship and Quality Evaluation [poor/satisfactory/good] Poor
- Pump Safety Evaluation [poor/satisfactory/good] Satisfactory
- Pump Operating Manual Evaluation [not included/poor/needs improvement/good] Good
Sampling and Testing Information
- Sample Location Manufacturer Warehouse
- Retail Price [USD] N/A
- Test Laboratory Name Schatz Energy Research Center
- Test Completion Date [MM/DD/YYYY] 4/6/2020
Awards
- Global LEAP Awards No